Accessories for Cable Locator Transmitters

Accessory set for locating transmitters with clear specifications (conductor sizes, lengths, jaw openings).

  • Direct-connection leads: Croc/alligator clips, insulated probes, fixed gauges and cable lengths
  • Induction clamps: Rated jaw diameter, permissible current/voltage, lead length
  • Grounding: Ground stakes and earth leads with defined length and terminations
  • Adapters & extensions: Series-specific connectors, extension leads
  • Carry cases: Form inserts for transmitters with accessory compartments

Carrying Case for Tx Transmitters
A highly durable nylon carrying case for the transmitter.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Connection Kit for Genny4 Transmitter
Contains the common connection accessories, including a direct connection lead, earth extension reel, earth stake and neodymium magnet.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Connection Kit for T1, TX-1, TX-5, TX-10 Transmitters
Contains the standard connection accessories, including a direct connection cable, ground return reel, Tx ground stake, and neodymium magnet.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Standard Connection Kit for Genny4 Transmitter
Used for the direct (galvanic) coupling of the Genny signal onto conductors.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Standard connection cable for transmitters T1, TX-1, TX-5, TX-10
Used for the direct (galvanic) coupling of the transmitter signal onto conductors.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Banana connection cable for transmitters T1, TX-1, TX-5, TX-10
Direct-connection cable with insulated 4 mm banana plugs and interchangeable crocodile clips for directly coupling the transmitter signal onto the utility line.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Ground Spike for Genny4 Transmitter
The ground spike is used to ground the Genny transmitter.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Ground Spike for Transmitters T1, Tx-1, Tx-5, Tx-10
Provides a reliable grounding point for the return path of the locating signal.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Grounding cable 10 m on reel (yellow)
The 10m cable on a practical cable reel is used to extend the ground lead of the direct-connection cable when no accessible or suitable grounding point is available on site.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Ground cable 10 m on reel (yellow) with magnetic contact
The 10 m long cable on a practical reel is used to extend the ground lead of the direct connection cable when no accessible or suitable grounding point is available on site. Includes magnetic contact.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Auxiliary cable 100m on Reel

Used to increase the distance between the ground stake and the transmitter during galvanic (direct) connection in order to extend the range of the transmitted signal. Multiple auxiliary cables on reels can be connected to simplify short-circuit loop connections on pipelines.

Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Transmitter Clamp 50 mm for Genny4 Sender
This clamp is used to inductively couple a Genny signal onto a specific conductor. It is particularly useful when direct signal coupling is not possible, or on live cables that cannot be de-energized.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Transmitter Clamp 100 mm for Genny4 Sender
This clamp is used to inductively couple a Genny signal onto a specific conductor. It is particularly useful when direct signal coupling is not possible, or on live cables that cannot be de-energized.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Transmitter Clamp 130 mm for Genny4 Sender
This clamp is used to inductively couple a Genny signal onto a specific conductor. It is particularly useful when direct signal coupling is not possible, or on live cables that cannot be de-energized.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Transmitter Clamp 215 mm for Genny4 Sender
This clamp is used to inductively couple a Genny signal onto a specific conductor. It is particularly useful when direct signal coupling is not possible, or on live cables that cannot be de-energized.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
100mm Signal Clamp for 201G Transmitter
Used to apply a signal to a specific cable or line. Particularly useful where a direct connection is not possible or for live cables that cannot be switched off. Can be used with the extension rod.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
50 mm Transmitter Clamp for Transmitters T1, Tx-1, Tx-5 und Tx-10
This clamp is used to apply a transmitter signal to a single cable or pipe. It is particularly useful on live cables that cannot be de-energized, or when a direct signal connection is not possible. It can also be used with the extension rod.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
1 to 20 (from a total of 33)

Why transmitter accessories?

Coupling quality drives range, selectivity and depth accuracy. Robust leads, clamps and induction tools provide a defined injection path—even in noisy urban corridors.

Typical components

  • Direct connection: connection/ground leads, clips, ground stakes
  • Contactless: signal clamps in various jaw sizes
  • Induction: induction plate or loop
  • Adapters & interfaces: connector/thread adapters, extensions, splitters
  • Power & protection: batteries, rechargeable packs, chargers, carry cases, covers

Selection guide

  • Use case: route tracing, service locating, identification, sheath/earth faults
  • Frequency & power: match to 512/640 Hz, 8–9 kHz, 33 kHz
  • Compatibility: connector type, clamp opening, cable length and device specs
  • Durability: IP rating, strain relief and rugged cables for outdoor work

Pro tips

  • Ensure a solid return path—good grounding reduces bleed-over
  • Vary frequency/mode in multi-utility corridors to verify results
  • Keep contacts clean and replace damaged leads promptly

FAQ

When should I use a signal clamp?
For contactless injection or identification of a single conductor without disconnecting it.
When is an induction plate useful?
When direct connection is not possible—induction couples the signal without contact.
What cable length should I choose?
As short as practical to minimize losses, while leaving enough slack for setup.
What power source is best?
Rechargeable packs for frequent/long jobs; quality primary cells for occasional use.