Accessories for Cable Locators & Utility Tracing

The right accessories unlock the full performance of your cable locator—from signal coupling and fault finding to safe transport. Choose induction clamps, direct connection leads, ground stakes/A-frames, sondes, carry cases, batteries & chargers as well as headsets/straps.

  • Clean coupling: Clamps & leads for direct or contactless signal injection
  • Pinpoint tools: Sondes and A-frames for non-metallic ducts and sheath/ground faults
  • Field ready: Protective cases, reliable power and comfort add-ons for long shifts

A-Frame Bag
Carrying bag for the A-Frame.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
PointMan Plus Mapping Software (for RD8200SG) // License
PointMan Plus Mapping Software (for RD8200SG) // License
License for one workstation (smartphone, tablet) with a validity of 12 months.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Receive Clamp 50mm
Used with a locating receiver to identify individual utility lines, often in densely packed areas.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Receive Clamp 100 mm
Used with a locating receiver to identify individual utility lines, often in densely packed areas.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Receive Clamp 130mm
Used with a locating receiver to identify individual utility lines, often in densely packed areas.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Small / High-Sensitivity Receive Antenna
Reception frequencies starting at 8 kHz, for simple cable identification or tracing metallic pipes or cables in walls, floors, or ceilings.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Medium Receive Antenna
It makes it easier to locate individual utilities laid in bundles. It is used to identify inaccessible small cables and other utility lines.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Large Receive Antenna with Flexible Handle
The receive antenna has a long, flexible handle that allows you to identify and assign hard-to-reach cable bundles in ducts and shafts.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
STR Receive Antenna
It is used with CD-equipped receivers to locate and identify individual cables using the CD signal from a Tx-10(B) transmitter. LEDs and directional arrows indicate the CD signal current direction.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
STR Receiver Clamp
The receiver clamp for CD (Current Direction) and signal current measurement is used to clearly identify a target conductor among several parallel lines, as well as to measure the transmitter’s signal current along the conductor.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Headphones
With a locating receiver combined, they are suitable for use in noisy environments.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Carrying Bag for Cable Locators (Receivers)
Padded carrying bag for transporting cable locating devices (receivers). Suitable for C.A.T4, SuperC.A.T4 and RD312.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Carrying Bag for the C.A.T4 / Genny4 System and the SuperC.A.T4 / T1
This padded bag can store a C.A.T/Genny or SuperC.A.T4/T1 transmitter and their accessories.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
1 to 20 (from a total of 21)

Why accessories?

The right tools determine range, selectivity and repeatability. Better coupling reduces interference, stabilizes depth readings and speeds up route tracing.

Typical components

  • Signal clamps: inject/identify current on individual conductors without breaking the circuit
  • Leads & grounds: secure direct connection and solid return path
  • A-frame: pinpoint sheath/earth faults with directional guidance
  • Induction plate/loop: fast, non-contact signal injection when access is limited
  • Sonde accessories: mounts, adapters and test tools
  • Power & protection: batteries, chargers, cases, pouches, screen protection

Selection guide

  • Use case: pre-scan, route proving, service locating, fault finding
  • Frequency & power: match to 512/640 Hz, 8–9 kHz, 33 kHz
  • Compatibility: connector type, clamp opening, device specifications
  • Durability: IP rating, cable robustness, strain relief for field work

Pro tips

  • Scan in passive and active modes before digging
  • Establish a clean return path; verify contact quality and grounding
  • Document measurements; change frequency to validate uncertain results

FAQ

When should I use a signal clamp?
To inject or identify current on a single conductor without disconnecting it.
What’s the purpose of an induction plate?
Non-contact signal injection where direct connection isn’t possible.
How does an A-frame help?
It locates sheath/earth faults along the route using directional and intensity cues.
What are the essential add-ons?
A connection/ground lead kit, a suitable signal clamp and—depending on tasks—an A-frame or induction accessories.