Cable & Pipe Locators – locate utilities with confidence

Our cable & pipe locators help you trace buried utilities quickly and safely. Systems combine a transmitter and receiver for active locating and offer field-ready features like depth indication and directional guidance.

  • Active locating: Apply signals via direct connection or induction
  • Versatile tasks: Trace metallic lines and locate sondes in non-metallic ducts
  • Fault finding: Optional A-frame to pinpoint sheath/insulation faults

Omni Marker II for Electricity**
Color: red
Frequency: 169.8kHz
Application: electricity**
Laying depth: up to 1.5m


The OMNI-Marker II is a spherical marker from Tempo® used to electrically mark utility points. The sphere is placed above the point to be marked, and the integrated transmitting coil automatically aligns itself.
 
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Locating Rod Ø15.0 mm / 350 lm Black
Mobile version with integrated copper strand and one start tip incl. shackle

Reel diameter 1500 mm, hot-dip galvanized
Rod diameter 15.0 mm
Start/end ferrule thread M12
Tensile strength 650 kg
Bending radius 1150 mm
Rod length 350 m
Weight 141 kg
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
215 mm Transmitter Clamp for Transmitters T1, Tx-1, Tx-5 und Tx-10
This clamp is used to apply a transmitter signal to a single cable or pipe. It is particularly useful on live cables that cannot be de-energized, or when a direct signal connection is not possible. It can also be used with the extension rod.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
STR Transmitter Clamp
With this clamp, a CD (Current Direction) or low-frequency signal from a transmitter is coupled onto a cable or pipe. The CD signal is useful for identifying individual utilities in densely packed areas. This clamp is suitable for signal frequencies below 1 kHz.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Transmitter Clamp Extension Rod
Used to increase the safety distance between the connection point and the operator (for transformer and substation environments). The rod length is approx. 50 cm and can be extended multiple times. Receiver clamps, transmitter clamps, and fault-finding probes can be extended.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Phase Transmitter for SCHUKO Sockets for Genny4
This accessory inductively couples the Genny signal via a standard power outlet onto live conductors, such as street distribution boxes.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Phase Transmitter for SCHUKO Sockets for Signal Transmitters T1, Tx-1, Tx-5, Tx-10
This accessory inductively couples the transmitter signal through a standard power outlet onto live conductors, such as street distribution boards.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Phase Transmitter for Genny4 Transmitter
This accessory is used to couple the Genny signal onto live conductors using crocodile clips.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Phase Transmitter for Transmitters T1, Tx-1, Tx-5, Tx-10
This accessory is used to couple the transmitter signal onto live conductors using crocodile clips.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Transport Case
Sturdy hard-shell case specially designed for the protection and transport of precision receivers, including transmitter and accessories. Regional variations exist, including wheeled case versions.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Rodding Snake Ø4.5 mm / 60 lm Blue
Standard version with 1 start bulb incl. eyelet

Reel diameter 330 mm, hot-dip galvanized
Push cable diameter 4.5 mm
Start/end sleeve thread M5
Tensile strength 170 kg
Bending radius 310 mm
Push cable length 60 m
Weight 4.4 kg
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Replacement Frame Ø550 mm
Standard version
Push cable diameter 6.0mm
Capacity 30-80m
Weight 4.5kg
 
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
MicroProbe MPL6-33 (M5)
  • Frequency 33kHz
  • Locating depth up to 2.3m
  • Probe diameter 6.4mm
  • Probe length 84mm
  • Connection thread M5 (Female)
  • Power supply: 1x BR425
  • Probe type: With spring joint
Delivery incl. batteries
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Long Marker for Wastewater
Color: Green
Frequency: 121.6 kHz
Application: Wastewater
Installation Depth: up to 2.5 m


The Marker 2500 is a disc marker from Komplex and is specifically designed for deep utility routes. Passive markers make it possible to electrically mark utility points. The “disc” is placed horizontally above the utility point that needs to be marked.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
Smart Marker SM 1500 for Wastewater
Color: Green
Frequency: 121.6 kHz
Application: Wastewater
Installation Depth: up to 1.5 m
RFID Chip: Yes


The MiM Smart Marker SM 1500 is a disc marker from Komplex. Each Smart Marker has a unique RFID to allow clear identification. Passive markers make it possible to electrically mark utility points. The “disc” is placed horizontally above the utility point that needs to be marked.
Prices are visible to registered users only.
plus 20% tax excl. Shipping costs
181 to 200 (from a total of 237)

How to choose the right locator

  • Use case: Route tracing, service drops or pinpoint fault locating
  • Frequencies & screens: Select operating frequencies and views (e.g. guidance/peak) for your environment
  • Accessories: Induction clamp for contactless coupling, sondes for non-metallic ducts, A-frame for faults
  • Documentation: Consider depth readout and logging if required

Safety & practice

Always locate before you dig, mark the path and verify depth. Watch for interference and adapt your locating strategy when signals are ambiguous.