Skip to content
INFICON Sensistor XRS9012 hydrogen leak detector in an open black carrying bag with shoulder strap
Central unit of the INFICON Sensistor leak detector with blue and white control panel and annotated features
Sensistor H12 hand probe held in one hand, compact sensor with connection cable
Operator in hi-vis vest and helmet checking a road with a Sensistor hydrogen leak detector and ground probe
Preview: INFICON Sensistor XRS9012 hydrogen leak detector in an open black carrying bag with shoulder strap
Preview: Central unit of the INFICON Sensistor leak detector with blue and white control panel and annotated features
Preview: Sensistor H12 hand probe held in one hand, compact sensor with connection cable
Preview: Operator in hi-vis vest and helmet checking a road with a Sensistor hydrogen leak detector and ground probe
Sensistor XRS9012 Hydrogen Leak Detector for Forming Gas NH 95/5
Mobile Preview: INFICON Sensistor XRS9012 hydrogen leak detector in an open black carrying bag with shoulder strap
Mobile Preview: Central unit of the INFICON Sensistor leak detector with blue and white control panel and annotated features
Mobile Preview: Sensistor H12 hand probe held in one hand, compact sensor with connection cable
Mobile Preview: Operator in hi-vis vest and helmet checking a road with a Sensistor hydrogen leak detector and ground probe

Sensistor XRS9012 Hydrogen Leak Detector for Forming Gas NH 95/5

Product No.:
590-012
Shipping time:
20 - 25 working days 20 - 25 working days (abroad may vary)
Sold and shipped by:
CfT Group GmbH – seller profile, from Traiskirchen warehouse (AT)
Country of manufacturer:
Sweden
Commodity code:
90271010
Manufacturer:
Sensistor – show manufacturer's address
INFICON AB
Wahlbecksgatan 25A
582 13 Linköping
Sweden
Email: support.sweden@inficon.com

plus 20% tax excl. Shipping costs Transport insurance per parcel according to goods value, included in the shipping costs.

Downloads & Media2 items · 1 category

Accessories & spare parts

Sensistor H12 hand probe held in one hand, compact sensor with connection cable
Hand-held probe for forming gas leak detection with the Sensistor XRS9012 leak detector.

- Dust filter at the measuring tip
- Standard accessory to the XRS9012 leak detector
- Connection via the C21 probe cable (3 m, 6 m or 9 m); 3 m included with the XRS9012
Prices are visible to registered users only.
Shippingtime: 20 - 25 working days

More from this range

Frequently asked questions

Repair & Service0
Do you offer calibration?

As an official service point, we offer calibration for cable locators, leak detection and measuring devices. For a large proportion of the devices sold on the market, we issue corresponding certificates. You'll find more information on our Service & Repairs page and at service@cft.at.

Was this helpful?Thanks for your feedback!
Can I get a loan device during the repair?
On request, we'll provide you with a loan device during the repair – at our standard rental rates. We'll be happy to clarify availability and details with you: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Who do I contact for technical problems?
Our support team is happy to help with technical problems. Write to us at kontakt@semperdeal.com and include the device type, the exact error message and – if possible – a photo. That way we can help you quickly and specifically.
Was this helpful?Thanks for your feedback!
Do you offer repairs?

Yes, we offer repair services for most of the appliances in our range. Please submit a repair request directly via our repair request form or contact us at kontakt@semperdeal.com.

Was this helpful?Thanks for your feedback!
How much does a repair cost?
Po otrzymaniu Twojego urządzenia przygotujemy kosztorys. Naprawa jest wykonywana dopiero po Twojej akceptacji. Ewentualną opłatę diagnostyczną podamy na zapytanie: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Do you offer an on-site service?
Yes. In Austria and Germany we offer an on-site service – from installation and instruction through to repair. Please arrange appointments at kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Prices & Discounts0
How can I see the prices?
As a B2B shop, we display our prices in the customer area after you log in. All prices are net, plus VAT. For selected products, prices are also visible without logging in – i.e. for guests. For special conditions, please contact us at kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Do you offer used or demo devices?
From time to time we offer tested used and demo devices. As availability varies, it's best to ask us directly about current offers: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Are there quantity discounts or graduated prices?
Yes. Depending on the product and order quantity, quantity discounts and graduated prices are possible. We'll be happy to prepare your individual quote: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Do you offer project pricing or framework agreements?
For large projects we offer individual project pricing and framework agreements. Just tell us about your project – we'll prepare a tailored offer for you: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Datasheets & Downloads0
Is a user manual included?
Yes, the appropriate user manual is included with every device. You'll also find the manual on the respective product page in the "Downloads & Media" section. We'll gladly provide a digital version by email on request as well: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Where can I find software or apps for the devices?
You can obtain the software and apps for the devices from the respective manufacturers' websites. In addition, you'll find all software solutions from the individual manufacturers and products bundled in our "Software" section. If you have any questions about installation, we're happy to help: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Where can I find technical data sheets?
You'll find the technical data sheets directly on the respective product page in the "Downloads & Media" section. If you can't find a particular data sheet, we'll be happy to send it to you by email: kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Returns & Warranty0
Can I return or exchange products?
No. SEMPERDEAL sells to businesses only; there is no right of withdrawal or return, not even for unused goods in their original packaging. If goods are defective or we have delivered the wrong item, please notify us without delay after delivery at kontakt@semperdeal.com; we will then tell you how to proceed. Please never send goods back unannounced.
Was this helpful?Thanks for your feedback!
What should I do if the goods arrive damaged?
Please document any transport damage immediately with photos and report it within 24 hours to kontakt@semperdeal.com. That way we can process the damage quickly for you.
Was this helpful?Thanks for your feedback!
Training Courses0
Can I book training for a device I already own?
Yes. Training can also be booked for devices you already own – regardless of whether you purchased them from us. We also offer refresher courses. Simply contact us at kontakt@semperdeal.com.
Was this helpful?Thanks for your feedback!
Technical Consulting8
Which device is right for my application?
We're happy to help. Just describe your application and we'll recommend the right device for you. You can reach us by email at kontakt@semperdeal.com, via chat, or by phone at +43 (0) 2252 53169.
Was this helpful?Thanks for your feedback!
At which sensitivity level should a leak be confirmed with the Sensistor XRS9012?Sensistor

The XRS9012 has 10 sensitivity levels; the highest, extremely sensitive levels help to identify suspect areas faster. However, a decision to excavate should only be made once the leak has been reconfirmed at level 5 or lower. If the signal is too weak, wait until the gas concentration increases or make a few holes for higher signals. Excavate only on signals that can be repeated over and over again.

Was this helpful?Thanks for your feedback!
How do you locate water leaks with the Sensistor XRS9012?Sensistor

Procedure:

  1. Establish the location, diameter and length of the pipe, empty the pipe and isolate the section to be tested.
  2. Inject the tracer gas at low pressure (0.5 to 1 bar) at one end and release it at the other; measure at the far end to check that the gas has reached the entire length.
  3. Wait until the gas from the leak has risen to the surface.
  4. Walk the pipe with the XRS9012 and the hand probe extension, stopping approximately every 50 cm to draw a new sample; sound and LED indicators guide you to the leak, typically to within ±1 m.

The method is suitable for distribution and service pipes up to 30 cm in diameter; on pipes in service, filling takes longer and the leak shows at the surface with a delay.

Was this helpful?Thanks for your feedback!
What do the error indications on the Sensistor XRS9012 mean?Sensistor

The XRS9012 gives off a pulsating acoustic alarm and the ON lamp blinks red when an error is detected. The lit LEDs indicate the cause:

  • LED 1 and LED 4 together: the cable or the probe is most likely not connected.
  • LED 1, 2, 3 or 4 alone: the cable or the sensor is most likely broken (LEDs 1 and 2 indicate low or high sensor temperature, LEDs 3 and 4 low or high sensor voltage).
  • LED 8: the battery voltage is below 5.0 V and the instrument needs to be charged.
Was this helpful?Thanks for your feedback!
When is the H21 hand probe used with the Sensistor XRS9012 and when the 8612 surface probe?Sensistor

The H21 hand probe is the standard accessory of the XRS9012, with the sensor at the probe tip; it is connected via the C21 probe cable with a length of 3, 6 or 9 m. For MAX mode, which compares the gas concentration at several test points, the H21 is suitable for measurements under manhole covers and the 8612 surface probe for measurements on manhole covers and hard toppings.

Was this helpful?Thanks for your feedback!
What is the difference between SEARCH and MAX mode on the Sensistor XRS9012?Sensistor

SEARCH mode is used to pinpoint the leak: the pitch of the signal rises as you approach the leak and falls as you move away. MAX mode compares the gas concentration at several points, e.g. under manhole covers, and helps to pre-locate leaks after a longer section has been filled with tracer gas. Place the probe and press MAX; the instrument measures for 10 seconds and then shows the reading. For comparable results, the probe must be placed in the same way at every point, and the sensitivity can only be changed in SEARCH mode.

Was this helpful?Thanks for your feedback!
How long does the tracer gas take to reach the surface when searching for leaks with the Sensistor XRS9012?Sensistor

This depends strongly on the soil type, the surface and the depth of the pipe. Guide values:

MaterialDepthTime
Dry sand1 m20 min
Dry soil / wet sand1 m1 h
Wet soil / dry clay1 m4 h
Wet clay1 m12 h
Asphalt5 cmup to several hours
Concrete20 cmseveral hours

Actual times can vary significantly depending on ground and pipe conditions.

Was this helpful?Thanks for your feedback!
What sensitivity and response time does the Sensistor XRS9012 have?Sensistor

Specifications:

Sensitivity0.7 ppm H₂ in air, up to 10 sensitivity levels
Response timeunder 1 s
Warm-up timeunder 10 s
Outputs10-LED bar graph indicator, 3.5 mm earphone jack
Batteryrechargeable lead batteries (gel electrolyte), 13 h at 20 °C, 6 h at −20 °C
ChargingAC charger 100–240 V AC or car charger 9–15 V DC; 5 minutes of charging give 20 minutes of leak detection
Casingaluminium, waterproof (IP55)
Ambient temperature−20 to 50 °C
Weight1.9 kg, 2.5 kg in the carrying case
Was this helpful?Thanks for your feedback!
How does leak detection with the Sensistor XRS9012 and 95/5 forming gas work?Sensistor

The cable or pipe under test is filled with forming gas consisting of 5% hydrogen and 95% nitrogen. At a leak, the tracer gas escapes and is detected by the hydrogen sensor, which on the XRS9012 is located at the tip of the probe. The sensor relies on diffusion and responds selectively to hydrogen. Applications include pressurized telecom cables (buried or ducted), water and gas pipes, gas-filled power cables and heating systems.

Was this helpful?Thanks for your feedback!

No matching answer found

Try different wording – or ask us your question below.

Question not found?

Ask us directly — we answer personally.

Thank you! We will get back to you soon.
Sending failed. Please try again later.